120 HF SSB SHAPE
Function: Selects the passband characteristics of the DSP filter for the SSB mode on the HF band.
Available Values: SOFT or SHARP
Default Setting: SHARP
SOFT: Primary importance is attached to the phase of the filter factor.
SHARP: Primary importance is attached to the amplitude of the filter factor.
121 HF SSB SLOPE
Function: Selects the shape factor of the DSP filter for the SSB mode on the HF band.
Available Values: STEEP, MEDIUM or GENTLE
Default Setting: MEDIUM
122 6M SSB SHAPE
Function: Selects the passband characteristics of the DSP filter for the SSB mode on the 50 MHz band.
Available Values: SOFT or SHARP
Default Setting: SOFT
SOFT: Primary importance is attached to the phase of the filter factor.
SHARP: Primary importance is attached to the amplitude of the filter factor.
123 6M SSB SLOPE
Function: Selects the shape factor of the DSP filter for the SSB mode on the 50 MHz band.
Available Values: STEEP, MEDIUM or GENTLE
Default Setting: MEDIUM
End of Menu Item Details "RX DSP Group"
|
SCOPE GROUP
124 SCOPE MODE
Function: Selects the operation mode of the Band Scope Monitor (CENTER mode or FIX mode).
Available Values: CENTER or FIX
Default Setting: CENTER
125 SCOPE SPEED
Function: Selects the Sweep Speed of the Band Scope Monitor.
Available Values: FAST or SLOW
Default Setting: FAST
126 SCOPE AUTO TIME
Function: Selects the Start cycle of the Auto Scope feature.
Available Values: OFF, 3, 5, 10, 30 or 60 sec
Default Setting: OFF
127 START DIAL SPEEED
Function: Selects the start condition of the Dial Auto Scope feature.
Available Values: 0.5, 1, 2, 4, 8, or 16 kHz/sec
Default Setting: 8 kHz/sec
128 CENTER SPAN FREQ
Function: Selects the desired frequency span of the CENTER mode Spectrum Scope.
Available Values: 20, 50, 100, 200, 500 or 1000 kHz
Default Setting: 100 kHz
129 FIX 1.8MHz
Function: Selects the scan start frequency of the FIX mode Spectrum Scope while monitoring on the 160 meter amateur band.
Available Values: 1800 ~ 1999 kHz (1 kHz steps)
Default Setting: 1800 kHz
130 FIX 1.8MHz SPAN
Function: Selects the desired frequency span of the FIX mode Spectrum Scope while monitoring on the 160 meter amateur band.
Available Values: 20, 50, 100, 200, 500 or 1000 kHz
Default Setting: 200 kHz
131 FIX 3.5MHz
Function: Selects the scan start frequency of the FIX mode Spectrum Scope while monitoring on the 80 meter amateur band.
Available Values: 3500 ~ 3999 kHz (1 kHz steps)
Default Setting: 3500 kHz
Cont'd Next Page Menu Item Details "Scope Group"
|