FTDX1200 Operating Manual Page 121

MENU MODE Cont'd

Previous Page    Index of Topics    Table of Contents    Index of Pages    Next Page

MENU ITEM DETAILS Cont'd

120 HF SSB SHAPE
Function: Selects the passband characteristics of the DSP filter for the SSB mode on the HF band.
Available Values: SOFT or SHARP
Default Setting: SHARP

SOFT: Primary importance is attached to the phase of the filter factor.

SHARP: Primary importance is attached to the amplitude of the filter factor.


121 HF SSB SLOPE
Function: Selects the shape factor of the DSP filter for the SSB mode on the HF band.
Available Values: STEEP, MEDIUM or GENTLE
Default Setting: MEDIUM


122 6M SSB SHAPE
Function: Selects the passband characteristics of the DSP filter for the SSB mode on the 50 MHz band.
Available Values: SOFT or SHARP
Default Setting: SOFT

SOFT: Primary importance is attached to the phase of the filter factor.

SHARP: Primary importance is attached to the amplitude of the filter factor.


123 6M SSB SLOPE
Function: Selects the shape factor of the DSP filter for the SSB mode on the 50 MHz band.
Available Values: STEEP, MEDIUM or GENTLE
Default Setting: MEDIUM


End of Menu Item Details
"RX DSP Group"


SCOPE GROUP

124 SCOPE MODE
Function: Selects the operation mode of the Band Scope Monitor (CENTER mode or FIX mode).
Available Values: CENTER or FIX
Default Setting: CENTER


125 SCOPE SPEED
Function: Selects the Sweep Speed of the Band Scope Monitor.
Available Values: FAST or SLOW
Default Setting: FAST


126 SCOPE AUTO TIME
Function: Selects the Start cycle of the Auto Scope feature.
Available Values: OFF, 3, 5, 10, 30 or 60 sec
Default Setting: OFF


127 START DIAL SPEEED
Function: Selects the start condition of the Dial Auto Scope feature.
Available Values: 0.5, 1, 2, 4, 8, or 16 kHz/sec
Default Setting: 8 kHz/sec


128 CENTER SPAN FREQ
Function: Selects the desired frequency span of the CENTER mode Spectrum Scope.
Available Values: 20, 50, 100, 200, 500 or 1000 kHz
Default Setting: 100 kHz


129 FIX 1.8MHz
Function: Selects the scan start frequency of the FIX mode Spectrum Scope while monitoring on the 160 meter amateur band.
Available Values: 1800 ~ 1999 kHz (1 kHz steps)
Default Setting: 1800 kHz


130 FIX 1.8MHz SPAN
Function: Selects the desired frequency span of the FIX mode Spectrum Scope while monitoring on the 160 meter amateur band.
Available Values: 20, 50, 100, 200, 500 or 1000 kHz
Default Setting: 200 kHz


131 FIX 3.5MHz
Function: Selects the scan start frequency of the FIX mode Spectrum Scope while monitoring on the 80 meter amateur band.
Available Values: 3500 ~ 3999 kHz (1 kHz steps)
Default Setting: 3500 kHz


Cont'd Next Page Menu Item Details "Scope Group"

Cont'd Next Page "Menu Mode"

Previous Page    Index of Topics    Table of Contents    Back to Top    Index of Pages    Next Page

FTDX1200 Operating Manual Page 121